EATON POWER XPERT 9395 UPS WITH LITHIUM-ION ENERGY STORAGE
Have high-power needs and not a lot of space?
We’ve can develop a system for you that’s sure to help.
The EATON Power Xpert 9395 UPS provides industry-leading efficiency and scalable battery runtimes in a small footprint, especially when paired with the new Samsung SDI lithium-ion battery for UPS.
This three-phase solution, with models offering power ratings from 225 kVA to 1200 kVA (including high-performance models), is perfect for large data centers, healthcare applications, multi-tenant data centers, light industry, and other critical systems. Lower your total total cost of ownership by leveraging longer-lasting and reduced-maintenance lithium-ion batteries and the ground-breaking Energy Saver System from EATON. Monitor and manage your 9395 UPS with the 10-inch color LCD touchscreen display.
Appropriate Use Cases: Aerospace, Large Data Centers, Healthcare, Multi-Tenant Data Centers, Light Industry, Telecommunications, and other critical systems!
The EATON 9395 series offers:
- 99% UPS efficiency without sacrificing reliability using Energy Saver System;
- Stronger power performance with double-conversion efficiency (up to 97% with the new high performance model) and Eaton’s exclusive Easy Capacity Test;
- Lowest total cost of ownership through, 33 percent less heat, and up to 20 percent more power in the same footprint with the high performance model;
- The highest reliability and availability with Hot Sync paralleling, superior battery management, inherent redundancy and a scalable architecture that adapts to increasing power requirements;
- Robust manageability with 10-inch color touchscreen display, superior control and connectivity and with an extensive service offering;
- The Intelligent Power Software Suite, which offers free monitoring, management and shutdown software ideal for protecting physical and virtual machines;
- Money savings and protecting the environment through energy efficient operation (ENERGY STAR® qualified UPS) and by not using inefficient and often-replaced lead-acid batteries.
Let us help you design your large-cabinet Lithium-Ion UPS solution! We are leading experts in the field of Lithium-Ion Battery solutions and high-capacity energy storage needs!
Benefits of Lithium-Ion
Lithium-ion chemistry has become safer, more reliable and more affordable as research has improved the energy storage technology. Lithium-ion has superior characteristics (when compared to valve-regulated lead acid, or VRLA, batteries) in UPS systems, resulting in longer life, higher energy density, flexible installation options, longer life, more charging cycles and a lower total cost of ownership.
Save Money
- 10-year performance warranty
- 15-year design life (replace fewer batteries over time)
- Reduces total cost of ownership
Save Space
- 8X cycle
- 40% smaller than lead acid
- 60% lighter than lead acid
- Megawatts of power in a small footprint
Reduce Risk
- 24/7 Battery Management System (BMS) monitoring
- Cell protection (temperature, current, over/under voltage) cell balancing, state of charge, health and alarms/reports.
- If abnormal conditions exist, the BMS will protect the system from damage by disconnecting the affected battery.
- BMS also optimizes voltages in each battery module to maximize performance and increase service life.
Contact N1 Critical Technologies for configuration options and backup runtimes, which can range from 10 minutes to an hour+ with the Eaton 93PM and Samsung Lithium-Ion battery cabinets!
EATON Power Xpert 9395 (480V standard/400V optional/600/575V optional)
Lowest total cost of ownership in the industry
• Energy Saver System (ESS) provides 99 percent efficiency without compromising reliability, by suspending power modules when double conversion is not required
• Lowers operational costs by delivering up to 97 percent efficiency in double-conversion mode
• Offers maximized efficiency in double conversion down to extremely light loads using Variable Module Management System (VMMS)
• Reduces HVAC costs by producing >33 percent less heat
• With up to 20 percent more power in the same footprint, the resulting 50 kW additional real power allows users to power 100 more servers, allowing for up to $120,000 in additional revenue monthly*
• Delivers 100 percent conditioned, perfect sine-wave output by isolating output power from all input power anomalies
• Eliminates the cost of load bank rentals and minimizes burn-in testing energy costs with the Easy Capacity Test
*Quantified by estimating monthly revenue of $1,200 per server
High reliability and robust manageability
• Provides unity power factor plus capabilities, which allows the UPS to supply the reactive current for non-power factor corrected loads without the need for derating
• When at or below 50–75 percent capacity, the 9395 high performance uninterruptible power modules (UPMs) automatically act as N+1 redundant systems, saving the cost and space required for separate redundant UPS and battery systems
• Handles up to 0.9 leading load power factors without de-rating UPS capacity
• HotSync patented load-sharing technology enables parallel operating of static converters without communication for sync or loadshare signals
• At-a-glance detection of power module status with optional LED lights
Scalability and flexibility
• Number of power modules per UPS can be specified, so capacity can flex to match data center growth
• Layout can be chosen to suit installation, such as back-to-back, L – shaped or integrated into switchgear
• Preferred bypass topology can be centralized or distributed and additional modules can be added as power load increases
• Centralized multi-module paralleled 9395 systems are supported by the Eaton System Bypass Module (SBM)
• More than 90 percent of materials used can be recycled, decreasing end-of-life impact
Product Snapshot | |
---|---|
Power Rating | 225-1100 kVA, High performance model: 200-1200 kW/kVA |
Voltage | 480V standard; 400V optional and 600/575V optional |
Frequency | 50/60 Hz |
Configuration | Tower |
Product Series | Powerware |
UPS Models | ||||
---|---|---|---|---|
Part Number | Power Rating | Voltage | ESS Efficiency | Double Conversion Efficiency |
9395 UPS Models (all models are TAA Compliant) | ||||
Power Xpert 9395 | 225 to 1100 kVA | 480V and 400V | 99% | 94% |
Power Xpert 9395 high performance 480V | 200 to 1200 kVA/kW | 480V | 99% | up to 97% |
Power Xpert 9395 high performance 400/415V | 200 to 1100 kVA/kW | 400/415V | 99% | up to 96% |
Power Xpert 9395 high performance 600/575V | 200 to 1100 kVA/kW | 600/575V | 99% | up to 96% |
Samsung SDI Batteries for UPS
Samsung SDI’s lithium-ion battery for UPS is capable of supplying a large current (450A) and is compatible with major global UPS companies.
Less Space/Weight
- Less space for battery room
- No structure reinforcement required
Longer Life
- Battery replacement deferral
- Enhanced reliability
Fast Charge/Discharge Rate
- No oversizing required
- Shorter charging time
Technical Specifications
Samsung Lithium-Ion Battery Cabinet
.tg td{font-family:Arial, sans-serif;font-size:14px;padding:10px 5px;border-style:solid;border-width:1px;overflow:hidden;word-break:normal;border-color:black;}
.tg th{font-family:Arial, sans-serif;font-size:14px;font-weight:normal;padding:10px 5px;border-style:solid;border-width:1px;overflow:hidden;word-break:normal;border-color:black;}
.tg .tg-us36{border-color:inherit;vertical-align:top}
.tg .tg-yw4l{vertical-align:top}
Item | Module | Rack | |||
---|---|---|---|---|---|
Model | U4-M020 | U6-M020 | UC-M010 | U4-R070 | U6-R035 |
Cell Capacity (Ah) | 67 | 67 | 35 | 67 | 67 |
Energy (kWh) | 2.0 | 2.0 | 1.0 | 70 | 35 |
Operating Voltage | 24~33.6 | 23~33.6 | 24~33.6 | 408~572 | 408~572 |
Dimensions (mm) (WxDxH) |
216x414x163 | 216x414x163 | 216x414x163 | 600x920x1,878 | 600x920x1,878 |
Weight (kg) | 17 | 17 | 17 | 745 | 550 |
Power Xpert 9395
For technical specifications on 9395 High Performance models, click links below:
Power Xpert 9395 high performance 480V | 200 to 1200 kVA/kW |
Power Xpert 9395 high performance 400/415V | 200 to 1100 kVA/kW |
Power Xpert 9395 high performance 600/575V | 200 to 1100 kVA/kW |
Power Xpert 9395 UPS Technical Specs
* The 275 kVA model is ENERGY STAR qualified.
UPS rating (0.91 power factor) |
|||||||||||
kVA | 225 | 250 | 275 | 450 | 500 | 550 | 650 | 750 | 825 | 1000 | 1100 |
kW | 205 | 228 | 250 | 410 | 450 | 501 | 592 | 683 | 751 | 910 | 1001 |
General characteristics |
|||||||||||
Efficiency | >94% (99% with Energy Saver System) For industry-leading 97% double-conversion, check out the 9395 high performance models (see links above) |
||||||||||
Parallel capability | 4 distributed, 32 with SBM | ||||||||||
Maximum modules per size | Up to 3 modules, 550 kVA, up to 4 modules, 825/1100 kVA | ||||||||||
Audible noise | <76 dBA @ 1 meter | ||||||||||
Altitude (max) | 1000m at 40°C (104°F) | ||||||||||
N+1 Redundancy Capable | Yes | ||||||||||
Field upgradeable | Yes | ||||||||||
System bypass module | Included | ||||||||||
Input characteristics |
|||||||||||
Voltage | 480V standard; and 400V available | ||||||||||
Voltage range | +10% / -15% | ||||||||||
Frequency range | 45-65 Hz | ||||||||||
Power factor | 0.99 (minimum) | ||||||||||
Input current distortion | <3.5% (no input filter required) | ||||||||||
Soft start capability | Yes | ||||||||||
Internal backfeed protection | Yes | ||||||||||
Output characteristics |
|||||||||||
Voltage | 480V standard; and 400V available | ||||||||||
Regulation | ± 1% | ||||||||||
Inverter | PWM with IGBT switching | ||||||||||
Voltage THD | <2% (100% linear load); <5% (non-linear load) | ||||||||||
Load power factor range | Up to a .9 power factor leading without derating | ||||||||||
Battery |
|||||||||||
Battery types | VRLA, AGM, Wet Cell, Lithium-ion | ||||||||||
Battery voltage | 480 V | ||||||||||
Temperature compensation | Optional | ||||||||||
Charging method | ABM technology or Float, Selectable | ||||||||||
Dimension and weights | |||||||||||
225 kVA, 250 kVA, 275 kVA | 52.8”w x 34.4”d x 73.9”h | 1900 lb | |||||||||
225, 250, 275 kVA redundant | 73.6”w x 34.4”d x 73.9”h | 3150 lb | |||||||||
450, 500, 550 kVA | 73.6”w x 34.4”d x 73.9”h | 3274 lb | |||||||||
450, 500, 550 kVA redundant | 102.9”w x 34.4”d x 73.9”h | 4654 lb | |||||||||
Field upgrade module, 225, 250, or 275 kVA | 29.3”w x 34.4”d x 73.9”h | 1380 lb | |||||||||
650, 750, 825 kVA | 140.3″w x 34.4″d x 73.9″h | 5550 lb | |||||||||
650, 750, 825 kVA +1 redundant | 169.6″w x 34.4″d x 73.9″h | 6930 lb | |||||||||
1000, 1100 kVA | 169.6″w x 34.4″d x 73.9″h | 7050 lb | |||||||||
General Characteristics |
|||||||||||
Control panel (LCD) | 10-inch Color Touchscreen with LED panel | ||||||||||
Battery startup | Standard | ||||||||||
Frequency conversion | Standard | ||||||||||
Multi-language | Standard | ||||||||||
Buildings alarm inputs | 5 (galvanic isolated) | ||||||||||
Options | |||||||||||
External maintenance bypass | |||||||||||
PDU, RPP, and STS | |||||||||||
Maintenance bypass module, matching cabinet, 2/3/4 breaker | |||||||||||
DC disconnects | |||||||||||
65 or 100 kAIC input breakers | |||||||||||
Certifications | |||||||||||
Safety | UL1778, cUL | ||||||||||
EMC | IEC 62040-2, EN50091 Class A (restricted access) | ||||||||||
PredictPulse remote monitoring service | |||||||||||
24×7 remote monitoring of UPS and battery alarms, online dashboard for real-time updates, mobile app for alarms and monthly report. PredictPulse requires the PXGX-UPS Card and Environmental Monitoring Probe | |||||||||||
Communications | |||||||||||
Software Compatibility | Power Xpert | ||||||||||
Communications Cards | Four communication bays standard. The following connectivity options can be installed at any time:
|
||||||||||
Remote Inputs/Outputs | Five building alarm inputs and one summary alarm contact (5A @ 120V) standard | ||||||||||
Remote Monitor Panel | Eight backlit status indicator lamps plus an audible horn | ||||||||||
Due to continuing product improvements, specifications are subject to change without notice |
Power Xpert 9395 high performance 480V
Power Xpert 9395 High Performance 480V UPS Technical Specs
UPS rating (unity power factor 1.0 ) | |||||||||||||||||
kVA | 200 | 225 | 250 | 275 | 300 | 400 | 450 | 500 | 550 | 600 | 675 | 750 | 825 | 900 | 1000 | 1100 | 1200 |
kW | 200 | 225 | 250 | 275 | 300 | 400 | 450 | 500 | 550 | 600 | 675 | 750 | 825 | 900 | 1000 | 1100 | 1200 |
General characteristics |
|||||||||||||||||
Efficiency | 99% with Energy Saver System Up to 97% in double conversion |
||||||||||||||||
Parallel Capability | 4 UPS units maximum for distributed bypass and 8 UPS units maximum with SBM | ||||||||||||||||
Maximum modules per size | Up to 2 modules 300 kW Up to 3 modules 600 kW Up to 4 modules 900/1200 kW |
||||||||||||||||
Audible noise | as low as 75dBA @ 1 meter* | ||||||||||||||||
Altitude (max) | 1000m at 40°C (104°F); 1000m at 35°C (95°F ) when UPM capacity is above 275 kW | ||||||||||||||||
N+1 Redundancy Capable | Yes | ||||||||||||||||
Field upgradeable | Yes | ||||||||||||||||
System bypass module | Included | ||||||||||||||||
Input characteristics | |||||||||||||||||
Voltage | 480V standard; 600V/575V and 400/415V also available |
||||||||||||||||
Voltage range | +10% / -15% | ||||||||||||||||
Frequency range | 45-65 Hz | ||||||||||||||||
Power factor | 0.99 (minimum) | ||||||||||||||||
Input current distortion | <3% (no input filter required) | ||||||||||||||||
Soft start capability | Yes | ||||||||||||||||
Internal backfeed protection | Yes | ||||||||||||||||
Output characteristics | |||||||||||||||||
Voltage | 480V standard; 600V/575V and 400/415V also available |
||||||||||||||||
Regulation | ± 1% | ||||||||||||||||
Inverter | PWM with IGBT switching | ||||||||||||||||
Voltage THD | <2% (100% linear load); <5% (non-linear load) | ||||||||||||||||
Load power factor range | Up to a .9 power factor leading without derating | ||||||||||||||||
Battery | |||||||||||||||||
Battery types | VRLA, AGM, Wet Cell, Lithium-ion | ||||||||||||||||
Battery voltage | 480 V | ||||||||||||||||
Temperature compensation | Optional | ||||||||||||||||
Charging method | ABM technology or Float, Selectable | ||||||||||||||||
Dimension and weights | |||||||||||||||||
200 kW, 250 kW, 275 kW, 300 kW | 52.5”w x 34.4”d x 74”h | 2150 lb (975 kg) | |||||||||||||||
200-300 kW redundant | 73.8”w x 34.4”d x 74”h | 3184 lb (1447 kg) | |||||||||||||||
400, 500, 550, 600 kW | 73.8”w x 34.4”d x 74”h | 3184 lb (1447 kg) | |||||||||||||||
400-600 kW redundant | 103”w x 34.4”d x 74”h | 4221 lb (1918 kg) | |||||||||||||||
Field upgrade module, 300 kVA/kW | 29”w x 34.4”d x 74”h | 1037 lb | |||||||||||||||
675, 750, 825, 900 kVA/kW | 141″w x 34.4″d x 74″h | 5236 lb | |||||||||||||||
675, 750, 825, 900 kVA/kW +1 redundant | 170.1″w x 34.4″d x 74″h | 6523 lb | |||||||||||||||
1000, 1100, 1200 kVA/kW | 170.1″w x 34.4″d x 74″h | 6523 lb | |||||||||||||||
General Characteristics | |||||||||||||||||
Control panel (LCD) | 10-inch Color Touchscreen with LED panel | ||||||||||||||||
Battery startup | Standard | ||||||||||||||||
Frequency conversion | Standard | ||||||||||||||||
Multi-language | Standard | ||||||||||||||||
Buildings alarm inputs | 5 (galvanic isolated) | ||||||||||||||||
Options | |||||||||||||||||
External maintenance bypass | |||||||||||||||||
PDU, RPP, and STS | |||||||||||||||||
Maintenance bypass module, matching cabinet, 2/3/4 breaker | |||||||||||||||||
DC disconnects | |||||||||||||||||
100 kAIC input breakers | |||||||||||||||||
Certifications | |||||||||||||||||
Safety | UL1778, cUL | ||||||||||||||||
EMC | IEC 62040-2,C3 limits | ||||||||||||||||
PredictPulse remote monitoring service | |||||||||||||||||
24×7 remote monitoring of UPS and battery alarms, online dashboard for real-time updates, mobile app for alarms and monthly report.
PredictPulse requires the |
|||||||||||||||||
Communications | |||||||||||||||||
Software Compatibility | Power Xpert | ||||||||||||||||
Communications Cards | Four communication bays standard. The following connectivity options can be installed at any time:
|
||||||||||||||||
Remote Inputs/Outputs | Five building alarm inputs and one summary alarm contact (5A @ 120V) standard | ||||||||||||||||
Remote Monitor Panel | Eight backlit status indicator lamps plus an audible horn |
Power Xpert 9395 high performance 400V
Power Xpert 9395 high performance 400V technical specs
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
General characteristics |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Efficiency | 99% with Energy Saver System Up to 96% in double conversion |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Parallel Capability | 4 UPS units maximum for distributed bypass and 8 UPS units maximum with SBM | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Maximum modules per size | Up to 1 module 275 kW Up to 2 modules 550 kW Up to 3 modules 835 kW Up to 4 modules 1100 kW |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Audible noise | as low as 75dBA @ 1 meter* | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Altitude (max) | 1000m at 40°C (104°F) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
N+1 Redundancy Capable | Yes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Field upgradeable | Yes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
System bypass module | Included | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input characteristics | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage | 400/415V; 480V and 600/575V also available | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage range | +10% / -15% (415V) +15% / -15% (400V) +15% / -10% (380V) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Frequency range | 45-65 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power factor | 0.99 (minimum) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input current distortion | <3% (no input filter required) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Soft start capability | Yes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Internal backfeed protection | Yes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Output characteristics | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage | 400/415V; 480V and 600/575V also available | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Regulation | ± 1% | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inverter | PWM with IGBT switching | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage THD | <2% (100% linear load); <5% (non-linear load) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Load power factor range | Up to a .9 power factor leading without derating | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Battery | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Battery types | VRLA, AGM, Wet Cell, Lithium-ion | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Battery voltage | 480 V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature compensation | Optional | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Charging method | ABM technology or Float, Selectable | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimension and weights | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
200, 225, 250, 275 kVA/kW | 52.5″ w x 34.4″ d x 74″ h | 1886 lb (857 kg) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
300, 400, 450, 500, 550 kVA/kW | 73.8″ w x 34.4″ d x 74″ h | 3184 lb (1447 kg) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
675, 750, 825 kVA/kW | 141″ w x 34.4″ d x 74″ h | 5236 lb (2375 kg) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
1000, 1100 kVA/kW | 170.1″ w x 34.4″ d x 74″ h | 6620 lb (3003 kg) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
General Characteristics | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Control panel (LCD) | 10-inch Color Touchscreen with LED panel | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Battery startup | Standard | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Frequency conversion | Standard | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Multi-language | Standard | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Buildings alarm inputs | 5 (galvanic isolated) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Options | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
External maintenance bypass | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PDU, RPP, and STS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Maintenance bypass module, matching cabinet, 2/3/4 breaker | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC disconnects | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
100 kAIC input breakers | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Certifications | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Safety | UL1778, cUL | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
EMC | IEC 62040-2,C3 limits | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
PredictPulse remote monitoring service | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
24×7 remote monitoring of UPS and battery alarms, online dashboard for real-time updates, mobile app for alarms and monthly report.
PredictPulse requires the |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Communications | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Software Compatibility | Power Xpert | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Communications Cards | Four communication bays standard. The following connectivity options can be installed at any time:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Remote Inputs/Outputs | Five building alarm inputs and one summary alarm contact (5A @ 120V) standard | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Remote Monitor Panel | Eight backlit status indicator lamps plus an audible horn |
Power Xpert 9395 high performance 600V
Power Xpert 9395 high performance 600V UPS technical specs
UPS rating (unity power factor 1.0 ) | ||||||||||||||
kVA | 200 | 225 | 250 | 275 | 300 | 400 | 450 | 500 | 550 | 675 | 750 | 825 | 1000 | 1100 |
kW | 200 | 225 | 250 | 275 | 300 | 400 | 450 | 500 | 550 | 675 | 750 | 825 | 1000 | 1100 |
General characteristics |
||||||||||||||||
Efficiency | 99% with Energy Saver System Up to 96% in double conversion |
|||||||||||||||
Parallel Capability | 4 UPS units maximum for distributed bypass and 8 UPS units maximum with SBM | |||||||||||||||
Maximum modules per size | Up to 2 modules, 275 kVA/kW Up to 3 modules, 550 kVA/kW Up to 4 modules, 825/1100 kW/kVA |
|||||||||||||||
Audible noise | as low as 75dBA @ 1 meter* | |||||||||||||||
Altitude (max) | 1000m at 40°C (104°F) | |||||||||||||||
N+1 Redundancy Capable | Yes | |||||||||||||||
Field upgradeable | Yes | |||||||||||||||
System bypass module | Included | |||||||||||||||
Input characteristics | ||||||||||||||||
Voltage | 600V/575V; 480V and 400/415V also available | |||||||||||||||
Voltage range | +10% / -15% | |||||||||||||||
Frequency range | 45-65 Hz | |||||||||||||||
Power factor | 0.99 (minimum) | |||||||||||||||
Input current distortion | <3% (no input filter required) | |||||||||||||||
Soft start capability | Yes | |||||||||||||||
Internal backfeed protection | Yes | |||||||||||||||
Output characteristics | ||||||||||||||||
Voltage | 600V/575V; 480V and 400/415V also available | |||||||||||||||
Regulation | ± 1% | |||||||||||||||
Inverter | PWM with IGBT switching | |||||||||||||||
Voltage THD | <2% (100% linear load); <5% (non-linear load) | |||||||||||||||
Load power factor range | Up to a .9 power factor leading without derating | |||||||||||||||
Battery | ||||||||||||||||
Battery types | VRLA, AGM, Wet Cell, Lithium-ion | |||||||||||||||
Battery voltage | 480 V | |||||||||||||||
Temperature compensation | Optional | |||||||||||||||
Charging method | ABM technology or Float, Selectable | |||||||||||||||
Dimension and weights | ||||||||||||||||
Field upgrade module, 275 kVA/kW | 29″ w x 34.4″ d x 74″ h | 1037 lb | ||||||||||||||
200, 225, 250, 275 kVA/kW | 102.9″ w x 34.4″ d x 74″ h | 4354 lb | ||||||||||||||
200-275 kW +1 redundant | 126.2″ w x 34.4″ d x 74″ h | 5683 lb | ||||||||||||||
300 kVA/kW | 126.2″ w x 34.4″ d x 74″ h | 5683 lb | ||||||||||||||
675, 750, 825 kVA/kW | 195″ w x 34.4″ d x 74″ h | 10050 lb | ||||||||||||||
675, 750, 825 kVA/kW +1 redundant | 224″ w x 34.4″ d x 74″ h | 11550 lb | ||||||||||||||
1000, 1100 kVA/kW | 224″ w x 34.4″ d x 74″ h | 11550 lb | ||||||||||||||
General Characteristics | ||||||||||||||||
Control panel (LCD) | 10-inch Color Touchscreen with LED panel | |||||||||||||||
Battery startup | Standard | |||||||||||||||
Frequency conversion | Standard | |||||||||||||||
Multi-language | Standard | |||||||||||||||
Buildings alarm inputs | 5 (galvanic isolated) | |||||||||||||||
Options | ||||||||||||||||
External maintenance bypass | ||||||||||||||||
PDU, RPP, and STS | ||||||||||||||||
Maintenance bypass module, matching cabinet, 2/3/4 breaker | ||||||||||||||||
DC disconnects | ||||||||||||||||
100 kAIC input breakers | ||||||||||||||||
Certifications | ||||||||||||||||
Safety | UL1778, cUL | |||||||||||||||
EMC | IEC 62040-2,C3 limits | |||||||||||||||
PredictPulse remote monitoring service | ||||||||||||||||
24×7 remote monitoring of UPS and battery alarms, online dashboard for real-time updates, mobile app for alarms and monthly report.
PredictPulse requires the |
||||||||||||||||
Communications | ||||||||||||||||
Software Compatibility | Power Xpert | |||||||||||||||
Communications Cards | Four communication bays standard. The following connectivity options can be installed at any time:
|
|||||||||||||||
Remote Inputs/Outputs | Five building alarm inputs and one summary alarm contact (5A @ 120V) standard | |||||||||||||||
Remote Monitor Panel | Eight backlit status indicator lamps plus an audible horn |